Programm Becker Motor endlimits

1. Bring the awning in the required lower endposition

2. Press the programm butto until you hear a one time "Klack" tone

Endlimits are programmed right now.

3. Now move the awning inwards until it closes, keeping your finger depressed on the up button (this is very important). The motor is torque sensing so no manual inward limit is required.